<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>40414</ErrorNumber>
<ErrorFamily>Media Handler</ErrorFamily>
<ErrorMessage>
MDH: Picker wrist cylinder is faulty
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_400/800_Autoloader</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
<ListItem><Text>Trendsetter_Series_4</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
If this error is reported, the picker wrist cylinder is probably faulty.
</text></DescriptionText>
<DescriptionText><text>
If there are problems during a pick, the firmware does extra steps to try and figure out
the real problem.  For this error to be reported, the picker will have tried to grab the
plate, but the wrist timed out moving out.  Even after releasing vacuum, the wrist still
would not come out.  The picker head was moved out, then back in to try and re-seal the wrist
cylinder.  The wrist was then moved back in to grab the plate, then the wrsit was moved out.
Still the wrist would not come out.  This could be a bad sensor, but the sensor is checked
before the wrist moves in the first time to grab the plate, and it had read TRUE at that time.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
A device error has occurred:
</text></DescriptionText>
<DescriptionText><text>
You may be able to continue by pressing the "resume" button onscreen (if present)
or by resetting the device and workstation.
</text></DescriptionText>
<DescriptionText><text>
For support under your service contract, contact the Creo Response Center at 1-(800) 472-2727
or online at http:\\eCentral.creo.com (or your local service representative)
</text></DescriptionText>
<DescriptionText><text>
To speed troubleshooting, please make a note of error numbers, the media type/size
and any information about the workflow or job that might be relevant.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
The wrist cylinder is leaking.
</Cause>
<Cause>
The wrist sensor may be intermittant.
</Cause>
<LastModified>
18-DEC-2001
Created.
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:26 2008 PST
</Updated>
<Links>
</Links>
</Error>